Chemical Oxidation of HPA

From MC Chem Wiki
Revision as of 02:57, 20 November 2019 by Jwelker (talk | contribs) (Created page with "When we were unsuccessful with the oxidation of oxybenzone both enzymatically and chemically, we turned to HPA for chemical oxidation. ==Making the Samples For Chemical Oxid...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

When we were unsuccessful with the oxidation of oxybenzone both enzymatically and chemically, we turned to HPA for chemical oxidation.

Making the Samples For Chemical Oxidation

2 mM HPA Buffer Stock Solution

Dissolved 30 mg of HPA in 100 mL of ph 5 buffer solution.

Potassium Permanganate Stock Solution


Preparing the final samples

Measured out 5 mL of the 2 mM HPA stock solution into 4 different scintillation vials. Added potassium permanganate solution in increasing concentrations to each vial (6 microliters, 12 microliters, 18 microliters, and 24 microliters).