Lignan Concentration

From MC Chem Wiki
Revision as of 18:00, 6 April 2021 by Tcoffman (talk | contribs)
Jump to navigation Jump to search

Materials and Methods

Lignans for Life Hydroxymatairesinol (HMR) Lignan was obtained from Amazon.com (Seattle, WA, USA), and 1,4-Dioxane and EtOH were obtained from Sigma Aldrich (St. Louis, MO, USA).

Solutions of 2 HMR Lignan capsules + 20 mL of 1,4-Dioxane and 4 HMR Lignan capsules + 40 mL of 1,4 Dioxane were prepared. These solutions were filtered and analyzed using the HPLC at absorbance wavelength of 270 nm and 28℃ using an acetonitrile (ACN) and 0.1% TFA gradient for 30 minutes. The first 15 minutes were run at 100% 0.1% TFA, 15-25 minutes at 100% ACN, and 25-30 minutes at 100% 0.1% TFA.

The solution of 4 HMR Lignan capsules in 40 mL of 1,4-Dioxane was used to fill ten 1.5 mL Eppendorf tubes with 1.0 mL of solution. These Eppendorf tubes were placed in a Savant Speedvac SC110 Concentrator (Holbrook, NY, USA) and spun overnight to remove the solvent. The pelleted solute in each Eppendorf tube was then resolubilized using 1 mL of EtOH.

The Lignan concentrate (10 μL) in 1 mL of H2O was ran on the HPLC at absorbance wavelength of 270 nm and 28℃ using an acetonitrile (ACN) and 0.1% TFA gradient for 30 minutes. The first 15 minutes were run at 100% 0.1% TFA, 15-25 minutes at 100% ACN, and 25-30 minutes at 100% 0.1% TFA.

Results and Discussion

Error creating thumbnail: Unable to save thumbnail to destination
Figure 1: HPLC analysis of varying concentrations of 2 HMR Lignan Capsules in 20 mL of 1,4-Dioxane and 4 HMR Lignan Capsules in 40 mL of 1,4-Dioxane.
Figure 1: HPLC analysis of 10 μL of Lignan concentrate in 1 mL of H2O