==June 16, 2016==
 
==June 16, 2016==
  
Concentration of acetaminophen is increased in preparation for Flash Chromatography. Figure 1 below shows the effect of increasing the concentration of the systems.
+
Concentration of acetaminophen is increased in preparation for Flash Chromatography. Figure 1 below shows the effect of increasing concentration on product formation.
 
[[File:APAP-IE-50mM-1ml-min.jpg|400px|Figure 1]]
 
[[File:APAP-IE-50mM-1ml-min.jpg|400px|Figure 1]]
 +
 +
It appears that at higher concentrations, the reaction will begin to form polymeric material, despite relatively low concentrations of Hydrogen Peroxide.
 +
 +
Sample B will be separated using Flash Chromatography.
 +
 +
It is important to not that we have reached the max absorbance of our instrument.
 +
 +
Figure 2 below shows a set of samples under identical conditions as Figure 1 except with a flow rate of 2 ml/min.
 +
[[File:APAP-IE-50mM-2ml-min.jpg|400px|Figure 2]]

Revision as of 00:47, 20 June 2016

June 16, 2016

Concentration of acetaminophen is increased in preparation for Flash Chromatography. Figure 1 below shows the effect of increasing concentration on product formation. Figure 1

It appears that at higher concentrations, the reaction will begin to form polymeric material, despite relatively low concentrations of Hydrogen Peroxide.

Sample B will be separated using Flash Chromatography.

It is important to not that we have reached the max absorbance of our instrument.

Figure 2 below shows a set of samples under identical conditions as Figure 1 except with a flow rate of 2 ml/min. Figure 2