Difference between revisions of "Peroxidase UV Vis assay"

From MC Chem Wiki
Jump to navigation Jump to search
 
(10 intermediate revisions by 2 users not shown)
Line 1: Line 1:
introduction...We are interested in measuring the peroxiase activity of a solution. We are going to isolate ovop from sea urchins and we need to know how actie the enzyme is. We are starting with HRP and ...
+
This research project involved the oxidation of guaiacol using the reaction between horseradish peroxidase and hydrogen peroxide. The purpose of this project was to develop a protocol for measuring the activity of a peroxidase using the UV-Vis.
 +
 
 
==Standard Mixing Procedure==
 
==Standard Mixing Procedure==
The mixture of Peroxidase UV-Vis assays requires the use of a Guaiacol stock solution and a hydrogen peroxide stock solution. The stock solutions are prepared as follows:
+
The mixture of Peroxidase UV-Vis assays requires the use of a Guaiacol stock solution and a hydrogen peroxide stock solution.  
 +
 
 +
The stock solutions are prepared as follows:
  
 
'''Guaiacol Stock Solution'''
 
'''Guaiacol Stock Solution'''
Line 19: Line 22:
 
The desired amount of peroxidase is then added to the assay before the UV-Vis is ran.
 
The desired amount of peroxidase is then added to the assay before the UV-Vis is ran.
  
==Example Data==
+
==References==
 +
[[Media:J._Biol._Chem.-1984-Deits-13525-33.pdf|Purification and Assay publication]]
 +
 
 +
==Progress as of December 2018==
 +
 
 +
The main focus of the first semester of this research project has been to develop an efficient lab protocol for measuring the activity of a peroxidase. Since we will eventually be working with sea urchin peroxidase, background research was done on how to properly care for sea urchins as well as how to make UV-Vis assays for sea urchin peroxidase. With this information, we developed a standard mixing protocol for the UV-Vis assay using HRP. Several weeks have been spent modifying this procedure to produce more consistent results. Brad has taught me how to use the kinetics function for the UV-Vis, how to analyze data using Igor, and how to use the mixing attachment for the UV-Vis. We have also set up the tank which will hold our sea urchins when they arrive next semester.
  
==Hi-Tech Mixing Procedure==
+
==Spring Semester 2019 Goals==
  
==Example Data==
+
Moving forward, we hope to establish a final lab protocol for measuring peroxidase. The beginning of the semester will focus on adjusting the sea urchins to their tank and effectively monitoring their environment. We will be collaborating with Laura Sanchez to synthesize the sea urchin ovoperoxidase.

Latest revision as of 19:58, 30 June 2020

This research project involved the oxidation of guaiacol using the reaction between horseradish peroxidase and hydrogen peroxide. The purpose of this project was to develop a protocol for measuring the activity of a peroxidase using the UV-Vis.

Standard Mixing Procedure

The mixture of Peroxidase UV-Vis assays requires the use of a Guaiacol stock solution and a hydrogen peroxide stock solution.

The stock solutions are prepared as follows:

Guaiacol Stock Solution

49.5 microliters of Guaiacol is added to a 25 mL pH 8.0 buffer solution, which is comprised of 25 mL of DI water and a 8.0 pH buffer tablet that has been mixed thoroughly.

Hydrogen Peroxide Stock Solution

17 microliters of hydrogen peroxide is added to 1 mL of DI water.

Assay

5.0 mL Guaiacol stock solution is added to a vial.

10 microliters of the hydrogen peroxide stock solution is added to the Guaiacol stock solution.

The desired amount of peroxidase is then added to the assay before the UV-Vis is ran.

References

Purification and Assay publication

Progress as of December 2018

The main focus of the first semester of this research project has been to develop an efficient lab protocol for measuring the activity of a peroxidase. Since we will eventually be working with sea urchin peroxidase, background research was done on how to properly care for sea urchins as well as how to make UV-Vis assays for sea urchin peroxidase. With this information, we developed a standard mixing protocol for the UV-Vis assay using HRP. Several weeks have been spent modifying this procedure to produce more consistent results. Brad has taught me how to use the kinetics function for the UV-Vis, how to analyze data using Igor, and how to use the mixing attachment for the UV-Vis. We have also set up the tank which will hold our sea urchins when they arrive next semester.

Spring Semester 2019 Goals

Moving forward, we hope to establish a final lab protocol for measuring peroxidase. The beginning of the semester will focus on adjusting the sea urchins to their tank and effectively monitoring their environment. We will be collaborating with Laura Sanchez to synthesize the sea urchin ovoperoxidase.